Przeglądanie stron 32
Building
type
Heat retention ability
Recom-
mended value
Light Low heat retention ability, e.g. prefab / wood-frame houses approx. 10h
Medium Moderate heat retention ability, e.g. house made from hollow blocks approx. 20h
Heavy High heat retention ability, e.g. brick house approx. 30h
Very heavy Very high heat retention ability, e.g. exterior and interior walls > 30cm approx. 60h
Passive Well-insulated, e.g. zero-energy housing approx. 100h
Fig. 55: Setting the building time constant
Menu item Parameter Factory setting
Building time
constant
0 - 100 h
According to
design! - 10 h
Press "Next".
Setting the standard heating load
Set the standard heating load (select with the
rotary knob and confirm with "OK"). The standard
heating load is obtained by multiplying the specific
heating load by the living area to be heated. You
can calculate the standard heating load from the
following table.
Building performance requirements
Year of construction Specific heating load
Up to 1970, uninsulated
120 - 180 W/m
2
1977 to 1984
70 - 100 W/m
2
1985 to 1995
50 - 70 W/m
2
New build, EnEv
40 - 50 W/m
2
New build, KfW 40/60
20 - 30 W/m
2
Zero-energy house
10 - W/m
2
Fig. 56: Setting the standard heating load
Menu item Parameter Factory setting
Standard
heating load
0 - 25 kW
According to
design! - 14.0
kW
Press "Next".